Your Global Center of Precision Cleaning Competence & Services
Zestron

Analytical Services

Residues remaining on surfaces can adversely affect the functional reliability of electronic assemblies, which in turn, can be very costly for the manufacturer and the end user.  To evaluate cleanliness, ZESTRON offers Basic and Advanced Analytics.

Surface Analysis

Adequate cleanliness level assessments of your electronic assemblies can be performed using methods such as the ZESTRON® Flux and Resin Test, surface tension analysis, Ionic Contamination measurements and Ion Chromatography.


Climatic Reliability / Long-term analysis
Assembly surface analysis prior to conformal coating or wire bonding can be performed using contact angle measurement methods as well as the ZESTRON® Ink Test.  For failure analysis assessments of electronic assemblies, methods such as the Water Stress Test and copper related surface deficiencies are readily available.

Bath Analysis
ZESTRON offers the following services to test the quality of your cleaning or rinsing bath:


Visual Inspection
To provide the required evidence of cleanliness, ZESTRON offers Visual Inspection Services with High Resolution Surface Analysis using a Keyence VHX 500 microscope with up to 1000x magnification.




CONTACT US TODAY TO REQUEST A QUOTE!

 

Search

Cleanliness assessment